BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Sprinkler Saves - ECPv6.11.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://www.sprinklersaves.co.uk
X-WR-CALDESC:Events for Sprinkler Saves
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/London
BEGIN:DAYLIGHT
TZOFFSETFROM:+0000
TZOFFSETTO:+0100
TZNAME:BST
DTSTART:20240331T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0100
TZOFFSETTO:+0000
TZNAME:GMT
DTSTART:20241027T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Europe/London:20240330T192000
DTEND;TZID=Europe/London:20240330T200000
DTSTAMP:20260506T100453
CREATED:20240408T115456Z
LAST-MODIFIED:20240408T120253Z
UID:10000461-1711826400-1711828800@www.sprinklersaves.co.uk
SUMMARY:Winchester Care Home Sprinkler Activation
DESCRIPTION:Credit images Hampshire & Isle of Wight Fire & Rescue Service \n\nDate of incident: 30 March 2024.\nTine of call; 19:20.\nTime of stop; 20:00.\nLocation; Winchester.\nUse of building; Residential Care Home.\nLocation of fire; Room.\nAutomatic Fire Suppression System; Sprinklers.\nFire Rescue Service; Hampshire & Isle of Wight Fire & Rescue Service.\n\nHampshire County Council should be applauded for their position protecting their most vulnerable residents from fire by installing sprinklers into all their residential and nursing care homes as part of a package of long-standing fire safety measures following this positive news story reported by Hampshire & Isle of Wight Fire & Rescue Service. \nA small fire within a residential and nursing care home for older adults some of whom are living with dementia was successfully extinguished by the premises sprinkler system. \nResidential care premises present a series of unique challenges with respect to fire safety. The needs of the occupants and the resources required to undertake an evacuation in these types of premises require careful consideration both in the design and ongoing operation of such buildings\, to ensure that an appropriate level of fire safety is provided. \nThe diminished senses that result from the ageing process may ultimately result in the occupants of residential care premises having a slower reaction time to raise an alarm\, and due to the residents’ reduced physical capabilities\, a slower response time to an alarm\, which may result in an increased evacuation time. All the above- mentioned factors combine to increase the risk of injury or fatality in a fire\, especially where assistance from carers may be restricted at night. \nwhere residents require assistance\, it is likely that the evacuation process will take longer\, and sprinklers provide significant benefits to address this risk. \nThe Incident \n\nFire crews were mobilised to reports of a fire following the activation of the premises automatic fire detection system\, sprinkler alarm.\nOn arrival it was identified that the premises emergency plan\, progressive horizontal evacuation had been implemented by staff moving residents away from the affected fire compartment with no injuries reported.\nUpon entry to the room of origin a small fire involving a plastic waste bin had been successfully contained\, extinguished by the activation of one sidewall sprinkler head located directly above the seat of the fire.\nNo further firefighting media was required with only minor fire\, smoke damage reported within the compartment of origin.\n\nIt should be remembered.  \n\nThe fire was extinguished\, controlled within the compartment of origin by the\n\n\nSprinkler system.\nPassive fire safety measures.\n\n(Providing effective fire protection requires both passive and active elements working in unison and complementing the roles of one another) \n\nMinimal fire damage was reported within the compartment of origin.\nNo further firefighting media was required.\nThe sprinkler system maintained the care homes continuity of providing care to their residents with minimal disruption\, valuable community asset saved.\n\n  \n Emergency Plan \nA robust emergency plan was available allowing the provision of vital information for the Fire Rescue Service to be shared by onsite representatives. Clarifying the location and provision of key elements of the active fire safety systems where present such as sprinklers and other forms of AFSS. The outcome of which will allow a robust onsite emergency response to be immediately actioned to assist the control of the sprinkler system during the fire incident and following a fire so that they can be reinstated. \nThe Sprinkler System \nCoverage was provided throughout the premises including the loft space\, water supply town mains\, dual pump. \nLinks/sources \n\nSprinkler Saves Review 2022/2023\nSprinkler Saves Spring Update No 4\nHampshire & Isle of Wight Fire & Rescue Service Press Release\nBAFSA Information File 14 Fire Sprinkler Systems in Care Homes\n\nIf you want to make a difference working in the fire sector\, we need your assistance…… \nTo make sprinklers the norm and not the exception – we need the evidence. Encouraging the FRS to promote\, collate\, report sprinkler activations to Sprinkler Saves UK will help to create a central and comprehensive record of fire incidents where sprinklers played their role in containing/controlling or extinguishing the fire. \nIf you hear of a save report it using this link \n  \n     
URL:https://www.sprinklersaves.co.uk/saves/winchester-care-home-sprinkler-activation/
LOCATION:Winchester
CATEGORIES:Residential
ATTACH;FMTTYPE=image/jpeg:https://www.sprinklersaves.co.uk/wp-content/uploads/2024/04/Extinguished-waste-bin-scaled.jpg
END:VEVENT
END:VCALENDAR