BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Sprinkler Saves - ECPv6.11.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:Sprinkler Saves
X-ORIGINAL-URL:https://www.sprinklersaves.co.uk
X-WR-CALDESC:Events for Sprinkler Saves
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/London
BEGIN:DAYLIGHT
TZOFFSETFROM:+0000
TZOFFSETTO:+0100
TZNAME:BST
DTSTART:20220327T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0100
TZOFFSETTO:+0000
TZNAME:GMT
DTSTART:20221030T010000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:+0000
TZOFFSETTO:+0100
TZNAME:BST
DTSTART:20230326T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0100
TZOFFSETTO:+0000
TZNAME:GMT
DTSTART:20231029T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Europe/London:20230201T112600
DTEND;TZID=Europe/London:20230201T122600
DTSTAMP:20260429T120312
CREATED:20230302T202026Z
LAST-MODIFIED:20230302T202105Z
UID:10000414-1675250760-1675254360@www.sprinklersaves.co.uk
SUMMARY:London Tall Building Residential Sprinkler Activation
DESCRIPTION:Fire Rescue Service; London Fire Brigade (LFB)\nIncident; Fire\nWhen; 1 February 2023\nTime of call; 11;26\nWhere\, Thamesmead\nOccupancy; Residential block of apartments (10 or more stories)\nAutomatic fire suppression system; Residential sprinkler system\n\nLFB have reported the above-mentioned incident resulting in the activation of the premises residential sprinkler system. \nThe premises\, Residential block of apartments of 12 stories\, incorporating a range of 2- and 3-bedroom apartments with a podium garden onsite concierge. \nIncident \n\nOn arrival crews identified that the fire was within the hallway of a second-floor apartment\nTwo concealed sprinkler heads actuated extinguishing the fire.\n5% of the apartment was damaged by fire\, with no injuries reported.\nThe cause of the fire is believed to have been accidental involving incense oil burner\nFirefighting actions\, breathing apparatus crews committed with one jet\, water supply via wet riser.\n\nThis incident demonstrates once again the benefits of installing sprinklers within residential tall buildings for firefighter safety. \n\nRapidly reducing the rate of production of heat and smoke allowing the fire officer crucial time to implement the operational tactical plan.\nAllowing firefighters to complete search and rescue operations by limiting fire development\, which  significantly reduces the risk of flashover.\nIntegrity of the means of escape\, maintained.\nFire contained within the compartment of origin.\nThis incident demonstrates that a correctly designed and installed sprinkler system can detect\, raise the alarm and control or in this case extinguish a fire at an early stage of development and activate an alarm.\n\n\nProtecting firefighters\nProtecting\, reducing risk to life\nProtecting property\n\nFurther guidance \n\nBAFSA\, Sprinkler Saves Annual Review\nLFB AFSS\n\n  \n  \n 
URL:https://www.sprinklersaves.co.uk/saves/london-tall-building-residential-sprinkler-activation/
LOCATION:thamesmead
CATEGORIES:Residential
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=Europe/London:20221026T140900
DTEND;TZID=Europe/London:20221026T163200
DTSTAMP:20260429T120312
CREATED:20221029T070650Z
LAST-MODIFIED:20221029T070650Z
UID:10000397-1666793340-1666801920@www.sprinklersaves.co.uk
SUMMARY:Thamesmead  Recyling Centre Fire
DESCRIPTION:Fire Rescue Service; London Fire Brigade (LFB)\nIncident; Fire involving Internal Industrial Shredder\nWhen; 26 October 2022\nTime of incident: 14:09\nTime of stop: 16:32\nWhere\, Thamesmead\, Nathan Way\nUse of premises; Recycling Centre\nFixed installation; Automatic fire suppression system (AFSS)\n\nLFB have reported the above-mentioned incident involving an industrial shredder. \nThe Incident  \n\nFour pumping appliances were mobilised  requiring 20 firefighters\nOn arrival crews identified that the fire involved the premises industrial shredder\nThe sprinkler system activated containing/controlling the fire\n\nOutcome \n\nMinimal disruption to business\nReducing damages\, costs to business and the economy as a whole\n\nKey message; As part of a holistic approach Automatic Fire Suppression Systems have been proven to be one of the most effective active fire protection measures containing/controlling these types of fires preventing large costly fires developin \nNational Fire Chiefs Council/Environment Agency \n\n The National Fire Chiefs Council\, recommends that sprinklers are provided in facilities providing waste management and recycling. There is growing evidence that sprinklers are highly effective in controlling fires in these establishments. Uncontrolled fires in waste and recycling facilities are often prolonged\, extremely resource intensive for fire and rescue services and partner authorities. They are also commonly disruptive to local communities and to travel infrastructure.\n\n The Environment Agency (EA) Fire Prevention plans (FPP) \n\nDid you know that EA requires FPP to be submitted with all permit variations and new permit applications (at application stage) for sites that store combustible waste. The FPP needs to be approved by the EA before a permit is granted.\nA fire prevention plan (FPP) is a standalone management system that details the prevention measures and procedures as well as mitigation methods in place to protect against fire whilst carrying out day to day operations on a site.\nA requirement for the FPP is that\, if you store waste in a building \, you must install a fire suppression system. This system should be proportionate to the nature and scale of waste management activities completed and the associated risks.\n\n Since the launch of the sprinkler saves website 7 previous incidents have been reported \n\nFareham Solid recovered fuel facility\nBristol Recycling Centre Centre\nShropshire Recycling Centre\nLondon Recycling Centre\nEnfield Recycling facility \nRufforth Recycling facility\nManchester Waste Site/recycling facility\n\nLinks \n\nBAFSA\, Sprinkler Saves Annual Review 2021/2022\nBritish Automatic Fire Sprinkle Association\, Information file\, Fire Suppression Systems for the Waste Management Industry
URL:https://www.sprinklersaves.co.uk/saves/thamesmead-recyling-centre-fire/
LOCATION:thamesmead
CATEGORIES:Industrial