BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Sprinkler Saves - ECPv6.11.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://www.sprinklersaves.co.uk
X-WR-CALDESC:Events for Sprinkler Saves
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/London
BEGIN:DAYLIGHT
TZOFFSETFROM:+0000
TZOFFSETTO:+0100
TZNAME:BST
DTSTART:20240331T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0100
TZOFFSETTO:+0000
TZNAME:GMT
DTSTART:20241027T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;VALUE=DATE:20240529
DTEND;VALUE=DATE:20240530
DTSTAMP:20260429T111351
CREATED:20240709T091822Z
LAST-MODIFIED:20240807T195906Z
UID:10000386-1716940800-1717027199@www.sprinklersaves.co.uk
SUMMARY:London Waste Recycling Facility Sprinkler Activation
DESCRIPTION:London Fire Brigade LFB have reported the following activation where the Automatic Fire Suppression System (AFSS) was recorded as being present and operated having an impact. The data around the incident provides powerful evidence as to the ability of fire sprinklers and other forms of AFSS in protecting our communities from fire. \n\nIncident; Fire\nWhen; 29 May 2024\nTime of call; 03:39\nWhere\, Sutton\nOccupancy; Waste Recycling Facility\nLocation of fire; Process/Production room\nAutomatic fire suppression System; Sprinklers\n\nIncident  \n\nFire involving batteries\, generators located in a process production room.\nActivating the premises sprinkler system in the room of origin\, raising the alarm\n1 sprinkler head activated.\nContaining\, controlling the fire to the room of origin.\nTotal fire damage 11-20sqm.\nFirefighting action: Main Jet.\n\nThe ¹ National Fire Chiefs Council (NFCC) have reported that UK Fire and Rescue Services (FRS) attend around 300 significant fires in waste sites each year which are often difficult to extinguish requiring multiple FRS resources for significant periods of time which can have a serious impact on the local community in the short or long term\, including: \n\nThe Environmental Impact\nPublic health impacts on responders and communities\nLarge scale financial loses and disruption.\nRoad closures\nHigh demand on FRS and other agency resources\n\nFRS are fully aware of the environmental impacts of fire publishing sustainability\, environmental reports with further guidance published by the government on environmental protection\, providing further guidance for FRS on preventing and dealing with incidents with the potential to pollute. \nActive fire protection systems\, specifically AFSS should be seen as part of a holistic approach minimising fire damage as part of a greener approach from the fire sector\, which is currently overlooked. The Waste Industry Safety and Health Forum (WISH) published “Reducing Fire Risk at Waste Management Sites” good practice guidance on the latest research and information available to achieve good fire risk management which includes an appendix focusing on suppression/extinguishing/fighting systems focusing on \n\nImportance of seeking competent advice for the installation of a fire suppression system\nThe system should be proportionate to the nature and scale of waste management activities completed and associated risks.\nChoosing the appropriate fire suppression system which may include.\n\n\nSprinklers\nManual open deluge system\nDeluge/water spray systems\nMobile foam trolley\nWater monitors/cannons/curtains\n\n\nThe design\, installation and maintenance of the proposed system is covered by an appropriate UKAS-accredited third-party certification scheme.\nImportance of liaising with insurers who may have specific requirements for fire suppression systems.\n\nThe recent London\, Herne Hill Waste Transfer Station Fire 8 September 2023\, clearly reminds us of the dangers these types of fires can bring to the local community\, if fire suppression had been installed could the outcome of been different? \nIt is reported that. \n\n100% of the building was alight with a partial collapse.\nLFB Mobilised 15 fire appliances requiring 100 firefighters.\n2x 32 metre turntable ladders used as water towers.\nThe fire had a significant impact on the local communities.\nFire suppression was not installed.\n\n           \nImages credit LFB Twitter \nDeputy Assistant Commissioner for the South West London Area\, Nick Davis\, said: “Firefighters have been continually tackling the fire at the waste transfer station in Herne Hill since it started on Friday morning. Controlled demolition on site allowed us to safely make progress and the fire was fully extinguished this morning\, which I know will come of huge relief to local residents. \n“This fire has had a significant impact on the communities in the surrounding area and I know how difficult it has been for people to keep their doors and windows closed during the heatwave. Local senior fire officers and members of our Community Engagement team are continuing to give advice to local residents and provide support. We are carrying out an investigation into the fire and we are fully supporting the Metropolitan Police Service’s investigation. \n“The challenging nature of the fire on site means that firefighters from across London have attended over the weekend. I would like to thank our operational staff\, control officers and enabling teams for their work to maintain our presence on site for over 80 hours and counting.” \n\nSprinkler Saves Uk\, Annual Review 2023/2024\nFire Sprinklers Greater London Review 2018-2021\nWish\, Reducing Fire Risk At Waste Management Sites\nLFB Herne Hill Waste Transfer Station press release\n¹ NFCC. National Operational Guidance\, Fires in waste sites\n\n  \n     
URL:https://www.sprinklersaves.co.uk/saves/london-waste-recycling-facility-suppression-activation/
LOCATION:Sutton
CATEGORIES:Industrial
ATTACH;FMTTYPE=image/heic:https://www.sprinklersaves.co.uk/wp-content/uploads/2023/11/IMG_2302.heic
END:VEVENT
END:VCALENDAR