BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Sprinkler Saves - ECPv6.11.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:Sprinkler Saves
X-ORIGINAL-URL:https://www.sprinklersaves.co.uk
X-WR-CALDESC:Events for Sprinkler Saves
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/London
BEGIN:DAYLIGHT
TZOFFSETFROM:+0000
TZOFFSETTO:+0100
TZNAME:BST
DTSTART:20240331T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0100
TZOFFSETTO:+0000
TZNAME:GMT
DTSTART:20241027T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Europe/London:20240512T203600
DTEND;TZID=Europe/London:20240512T215200
DTSTAMP:20260430T232118
CREATED:20240522T130133Z
LAST-MODIFIED:20240522T135605Z
UID:10000368-1715546160-1715550720@www.sprinklersaves.co.uk
SUMMARY:Stowmarket open sided basement car park sprinkler activation
DESCRIPTION:Credit BM Sprinklers (image taken following reinstatement of the sprinkler system)   \n This incident provides further evidence on the benefits of sprinklers for car park fires which have become increasingly prevalent as the automotive industry has developed as cars have advanced\, so has the risk of fires. \n\nDate of incident;12 May 2024\nTine of call; 20:36.\nTime of stop; 21;52\nLocation; Stowmarket\, Suffolk\nUse of building; Low-rise purpose-built block of flats\nIncident; Motorbike fire.\nLocation of fire; Open sided Basement Car park\nAutomatic Fire Suppression System; Sprinklers.\nFire Rescue Service; Suffolk Fire & Rescue Service\n\nBackground to the installation of the sprinkler system \n\nThe premises consists of two residential low-rise block of flats\, blocks A & B.\nBlock B\, constructed in 2016 with an open sided basement car park\, block A refurbished.\nAt the time of construction\, the developer proposed a fire hydrant within the curtilage of the development to meet the specifications detailed in Part B5 of Approved Document B (ADB)Volume 1.\nThe location of the fire hydrant could not be confirmed at the time of consultation\, it was assumed that the location of the fire hydrant would be located at the rear of block A.\nThe access route from block A was deemed unsuitable for fire appliance access\, preventing a fire pumping appliance to be within 45 metres of all points within the development.\n\nIt was agreed with the developer as a compensatory trade off measure by SFRS that a sprinkler system conforming to the relevant code of practice\, standard would be installed within the dwellings and car park area. \nThe Incident  \n\nSFRS mobilised 4 fire appliances to a fire involving a motor bike which had caught light in an open sided basement car park.\nOn arrival it was identified that the premises sprinkler system had actuated within the car park area containing\, controlling the fire preventing further fire spread.\n6 sprinkler heads activated (VK468) with the water supply provided from a 6000-litre water tank.\nFirefighters wearing breathing apparatus extinguished the fire using 1x hose reel jet.\nAt the time of the fire no other motor vehicles were located adjacent to the motor vehicle with minor fire damage reported to light fittings\, electrics located above the seat of the fire.\nNo injuries or casualties reported\nThe cause of the fire is currently under investigation\n\nImpairment of active fire protection system \nWhere buildings and equipment are provided with active fire protection measures such as a sprinkler system protecting life and in some cases property protection. It is essential that the fire protection measures in a building can function effectively in the event of a fire. It is important that arrangements are in place to ensure the responsible person\, building manager for the premises is aware that following the activation of an active system such as a sprinkler system provisions are in place allowing for the immediate reinstatement of the sprinkler system following a fire. \nIt should be remembered.  \n\nAt the time of construction\, statutory legislation required sprinklers to be installed in residential block of flats of 30m and above.\nThere is no requirement for sprinklers to be installed in car parks\, instead reliance is place upon smoke ventilation either natural or mechanical.\nIf the requirements of ADB\, B5 had been complied with\, we could be looking at a more significant fire because sprinklers were not installed.\nSprinklers were only installed as a trade-off due to the requirement of B5 not being complied with.\n\nCar parks \nThe British Automatic Fire Sprinkler Association fully supports the recommendations made by the National Fire Chiefs Council within their Automatic Fire Suppression System (AFSS) position statement. \n\nRecommend AFSS be required in open sided car parks to protect property\, including the fabric of the building.\nStrongly recommend AFSS be required in\n\n\nEnclosed car parks\, as is common in Europe.\nAutomated car parks\, due to the extra density of fire loading created by stacking cars in carousel or racking systems.\n\nLinks/sources \n  \n\nSprinkler Saves Review 2023/24\nBAFSA Sprinkler Focus AFSS should be essential life safety feature in car parks\nSprinkler Saves Spring Update No 4\nNFCC Position Statement AFSS\nADB Volume 1\nBAFSA Information file Sprinklers in car parks\nProtecting against car park fires-How to prevent and minimize risks\n\nIf you want to make a difference working in the fire sector\, we need your assistance…… \nTo make sprinklers the norm and not the exception – we need the evidence. Encouraging FRS and those in the sprinkler community to promote\, collate\, report sprinkler activations to Sprinkler Saves UK which will help to create a central and comprehensive record of fire incidents where sprinklers played their role in containing/controlling or extinguishing the fire. \nIf you hear of a save report it using this link. \n     
URL:https://www.sprinklersaves.co.uk/saves/stowmarket-open-sided-basement-car-park-sprinkler-activation/
LOCATION:Stowmarket
CATEGORIES:Residential
ATTACH;FMTTYPE=image/png:https://www.sprinklersaves.co.uk/wp-content/uploads/2024/05/Opensided-carpark-fire.png
END:VEVENT
END:VCALENDAR