BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Sprinkler Saves - ECPv6.11.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://www.sprinklersaves.co.uk
X-WR-CALDESC:Events for Sprinkler Saves
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/London
BEGIN:DAYLIGHT
TZOFFSETFROM:+0000
TZOFFSETTO:+0100
TZNAME:BST
DTSTART:20240331T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0100
TZOFFSETTO:+0000
TZNAME:GMT
DTSTART:20241027T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Europe/London:20240424T000000
DTEND;TZID=Europe/London:20240524T120000
DTSTAMP:20260615T121620
CREATED:20240903T151644Z
LAST-MODIFIED:20240903T151644Z
UID:10000475-1713916800-1716552000@www.sprinklersaves.co.uk
SUMMARY:Norfolk Domestic Retrofitted Sprinkler Activation
DESCRIPTION:Credit image ReCom fire protection ltd\n\nDate of incident; 24 April  2024\nLocation; Norfolk\nUse of building; Dwelling flat/maisonette\nIncident; fire.\nLocation of fire; Living room\nAutomatic Fire Suppression System; BS9251:2021\nFire Rescue Service; Norfolk Fire Rescue Service (SWFRS)\n\nThe vast majority of reported sprinkler activations to Sprinkler Saves Uk are for residential tall building activations\, it is therefore refreshing to be informed of a domestic sprinkler activation which provides further evidence that the installation of fire sprinklers as part of a package of fire safety measures\, saves lives\, prevents injury minimizes property damage in a variety of occupancies. \nSummary \nFirstly\, our gratitude for the support of both NFRS and Recom Fire Protection Ltd for reporting this positive news story reaffirming the importance of reporting sprinkler activations to Sprinkler Saves Uk allowing trends\, anomalies to be identified in the emerging UK sprinkler firefighting industry allowing the continued review of technical standards ensuring best practice within the sprinkler\, fire industry. \nIn this case the \n\nDecision taken by the social landlord to Install a domestic sprinkler system within a dwelling flat/maisonette\, providing a further layer of safety protecting a vulnerable community member from fire as part of a package of fire safety measures.\nImportance of sprinkler coverage within bathrooms\, shower rooms and toilets.\n\nIt is proven that the installation of fire sprinklers as part of a package of fire safety measures\, saves lives\, prevents injury and minimizes property damage. It’s the equivalent of having a firefighter in your premises 24 hours a day\, 7 days a week. \nPromoting further evidence to the reliability and effectiveness of sprinkler systems following the two recent reports conducted ¹Optimal Economics\, and commissioned by the National Fire Chiefs Council\, National Fire Sprinkler Network into the performance\, reliability\, and effectiveness of sprinkler systems in controlling and extinguishing fires. \nThe reports found that: \n\nSprinklers are 99% efficient in extinguishing or controlling a fire.\nSprinklers are 94% efficient in their ability to operate.\n\nThe provision of a sprinkler system does not neglect the need for other fire practical precautions or provisions where the person is at higher-than-average risk from fire\, unable to self-evacuate in the event of a fire. \n Sprinkler System Specification \n\nBS9251;2021\nCategory 1\nDedicated tank and pump located within the garage of the premises\nRetrospective install with fabricated boxing in of the sprinkler system\nCoverage dwelling including garage\nGSM autodialer/external sounder/beacon\n1 sidewall sprinkler head\, VK480 activated\n\nThe Incident \n\nPrimary fire within a living room involving textiles\, clothing\nFire crews were mobilised to reports of a fire following an emergency call received from the remote alarm receiving centre.\nUpon arrival\, fire crews assisted Mr D from the property\, proceeded to extinguish a small fire in the living room involving textiles\, clothing.\nA further seat of fire was identified within the bathroom\, it was established that the resident had tried to extinguish the fire by removing the textiles/clothing which were alight to the bath tub in the adjacent bathroom.\nFirefighters identified that the sprinkler head within the bathroom had activated.\nThe circumstances regarding the activation of the sprinkler system are not conclusive as limited fire growth was reported within the bathroom allowing the sprinkler head to activate.\nIt is reported that Mr D was physicaly trying to silence the premises fire alarm before the arrival of NFRS\, while carrying out this action Mr D may of mistook the sprinkler head as the fire alarm resulting in the activation of the head.\nThe fire within the bathtub was extinguished by the activation of the sprinkler head\n\n. \n     \nCredit image ReCom fire protection ltd \nEmergency Plan  \n\nInformation was available onsite for NFRS to clarify the location and provision of key elements of the active fire safety systems.\nAllowing a robust onsite emergency response to be actioned to assist with the control of the sprinkler system at the conclusion of the fire incident.\nIt is reported that the tank was 70% depleted running for 12 minutes before the intervention of NFRS\n\nReinstatement of the Fire Protection Measures \n\nIt is paramount that fire protection measures in buildings can function effectively in the event of a fire. To achieve this the premises emergency plan should include that arrangements are in place allowing the immediate reinstatement of the sprinkler system.\nIt is a requirement of the Regulatory Reform (Fire Safety) Order for the responsible person to implement the appropriate arrangements for the effective planning\, organisation\, control\, monitoring of the preventive and protective measures.\nAny delay could compromise the safety of the occupants in the event of a further fire within the building due to the sprinkler system being offline.\n\nBenefits of a residential sprinkler system  \n It should be remembered that a correctly designed and installed sprinkler system \n\nIs an effective fire safety measures as part of a package of fire safety measures\nReduces the heat output from fire by reducing its growth\, containing\, controlling or in some cases extinguishing the fire\nInitiates the appropriate emergency procedures by sounding a sprinklered local alarm\nAllows more time for the occupants to escape to safety or be rescued\, protects firefighters\n\nLinks/sources \n\nSprinkler Saves Review 2023/2024\nSprinkler Saves Spring Update No 5\n¹Efficiency and Effectiveness of Sprinkler Systems in the United Kingdom: An Analysis from Fire Service data\nIn support of this publication a supplementary publication Incidence of Deaths and Injuries in sprinklered buildings was published\n\nIf you want to make a difference working in the fire sector\, we need your assistance…… \nTo make sprinklers the norm and not the exception – we need the evidence. Encouraging FRS and those in the sprinkler community to promote\, collate\, report sprinkler activations to Sprinkler Saves UK which will help to create a central and comprehensive record of fire incidents where sprinklers played their role in containing/controlling or extinguishing the fire. \nIf you hear of a save report it using this link. \n    \n 
URL:https://www.sprinklersaves.co.uk/saves/norfolk-domestic-retrofitted-sprinkler-activation/
LOCATION:Norfolk
CATEGORIES:Domestic
ATTACH;FMTTYPE=image/png:https://www.sprinklersaves.co.uk/wp-content/uploads/2024/08/Norfolk-2.png
END:VEVENT
END:VCALENDAR