BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Sprinkler Saves - ECPv6.11.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:Sprinkler Saves
X-ORIGINAL-URL:https://www.sprinklersaves.co.uk
X-WR-CALDESC:Events for Sprinkler Saves
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/London
BEGIN:DAYLIGHT
TZOFFSETFROM:+0000
TZOFFSETTO:+0100
TZNAME:BST
DTSTART:20210328T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0100
TZOFFSETTO:+0000
TZNAME:GMT
DTSTART:20211031T010000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:+0000
TZOFFSETTO:+0100
TZNAME:BST
DTSTART:20220327T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0100
TZOFFSETTO:+0000
TZNAME:GMT
DTSTART:20221030T010000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:+0000
TZOFFSETTO:+0100
TZNAME:BST
DTSTART:20230326T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0100
TZOFFSETTO:+0000
TZNAME:GMT
DTSTART:20231029T010000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:+0000
TZOFFSETTO:+0100
TZNAME:BST
DTSTART:20240331T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0100
TZOFFSETTO:+0000
TZNAME:GMT
DTSTART:20241027T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Europe/London:20240609T080000
DTEND;TZID=Europe/London:20240609T170000
DTSTAMP:20260429T120354
CREATED:20240609T192920Z
LAST-MODIFIED:20240609T193044Z
UID:10000379-1717920000-1717952400@www.sprinklersaves.co.uk
SUMMARY:Newport South Wales Chip Pan Sprinkler Save May 2024
DESCRIPTION:                  \n\n\nImage taken from BAFSA video chip pan demonstration          Credit RSP Sprinklers \nOur thanks to RSP sprinkler systems for reporting this incident demonstrating the benefits of residential sprinklers for life safety playing a significant role\, as part of an appropriate package of fire safety measures reducing the impact of fire on people\, firefighters\, property and the environment. \nDebunking the myth\, residential sprinklers as an extinguishing media should not be used on chip pan fires. \nIt is reported that South Wales Fire Rescue Service were mobilised to a fire within a residential block of flats\, on arrival it was identified that a kitchen fire involving a chip pan within a flat had been successfully extinguished\, contained to the room of origin by the activation of one sidewall sprinkler head. The resident required minor medical attention stating the fire was extinguished by the sprinkler system within 2 minutes \nKey facts \n\nThe fire was extinguished\, controlled within the compartment of origin\nThe activation of the sprinkler system reduced the heat output from the fire by reducing its growth\, allowing more time for the occupants to escape to safety or be rescued.\nNo further firefighting was required by South Wales Fire Rescue Service\nThe sprinkler system provided vital protection for the residents dwelling\, belongings\, personal processions.\n\nObservations/comments \n\nIt should be remembered the installation of a life safety Automatic Fire Suppression System is to reduce the rate of heat and smoke allowing more time for the occupants to escape to safety or be rescued clearly demonstrated following the successful conclusion to this incident.\n\n\nReinstatement of the system\, where buildings and equipment are provided with active fire protection measures such as a sprinkler system protecting life and in some cases property protection. It is essential that the fire protection measures in a building can function effectively in the event of a fire. It is important that arrangements are in place to ensure the responsible person\, building manager for the premises is aware that following the activation of an active system such as a sprinkler system provisions are in place allowing for the immediate reinstatement of the sprinkler system following a fire.\n\nIt is noted following the successful conclusion of this incident: – \n\nFrom receiving a call via the sprinkler company’s 24-hour emergency line the call out engineer was on site within 30 minutes.\nThe system was reinstated within 1 hour 40 minutes.\n\nIn England cooking fires are the most common type of accidental fire reported for the period 2013/2014 to 2022/2023 with over 1100 fires. We still see reports from the Fire Rescue Service (FRS) that where the occupant is present at the time of a chip pan fire\, they have tried to extinguish the fire themselves by placing the oil pan under the tap in the kitchen sink or throw water on the pan causing the oil to explode causing serious injury allowing further fire to spread. \nSprinkler Saves UK have reported multiple incidents involving chip pan fires on each occasion the fire was extinguished\, contained\, or controlled. \n\nLincoln\, 7 August 2021\nTonypandy\, Rhondda\, 29 December 2021\nFlint 3 June 2021\nSouth Yorkshire 26 August 2022\nLondon 21 August 2023\n\nBAFSA have released a comprehensive video that demonstrates the clear benefits of sprinklers involving chip pan fires\, click here to open.  Fire statistical data collated from incidents attended by fire and rescue service involving dwellings for the financial year 2019/20 confirmed that 1494 incidents took place involving chip pan fires \nLinks/sources \n\nSprinkler Saves Review 2023/24\nSprinkler Saves Spring Update No 4\nNottinghamshire FRS Press release chip pan fires\n\nIf you want to make a difference working in the fire sector\, we need your assistance…… \nTo make sprinklers the norm and not the exception – we need the evidence. Encouraging the FRS to promote\, collate\, report sprinkler activations to Sprinkler Saves UK will help to create a central and comprehensive record of fire incidents where sprinklers played their role in containing/controlling or extinguishing the fire. \nIf you hear of a save report it using this link \n         
URL:https://www.sprinklersaves.co.uk/saves/newport-south-wales-chip-pan-sprinkler-save-may-2024/
LOCATION:Newport
CATEGORIES:Residential
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=Europe/London:20220422T002400
DTEND;TZID=Europe/London:20220422T133400
DTSTAMP:20260429T120354
CREATED:20220629T200258Z
LAST-MODIFIED:20220629T200307Z
UID:10000371-1650587040-1650634440@www.sprinklersaves.co.uk
SUMMARY:Newport Industrial Sprinkler Activation
DESCRIPTION:Fire Rescue Service; South Wales Fire and Rescue Service (SWFRS)\nDate of incident; 22 April 2022\nTime of call; 00:24\nLocation; Newport\nPurpose group; Industrial Processing\nIncident; Fire\nLocation of Incident; Ground floor process room\nAutomatic Fire Suppression System (AFSS); Sprinkler System\n\nThe Incident \n\nSWFRS have reported the above-mentioned fire involving the mobilisation of three pumping appliances\, involving an electrical appliance\nThe fire was contained/controlled by the actuation of one fire sprinkler head with minimal fire damage reported in the vicinity of the incident\n\nBusiness Continuity  \n\nMajor fire avoided preventing major disruption in the wider community\nBusiness impact minimal preventing financial and equipment losses\nMinor interruption to the day to day running of the business\n\nEnvironmental Benefits of Sprinklers \n\nC02 emissions dramatically reduced\nReducing excess water used by the FRS\, eliminating water supply contamination\nMaterials and resources required to repair and rebuild the premises not required reducing CO2 emissions\n\nWhen you compare this incident to a major industrial fire reported by the Business Sprinkler Alliance involving a laundry business where SPRINKLERS WERE NOT FITTED the devastating impact of fire on businesses can clearly be identified. \n\nFire Rescue Service Resources required; 12 fire pumping appliances\, 2 Aerial Appliances over 60 firefighters\nWarehouse destroyed by the fire\nMajor business disruption\, requiring temporary site\n\nIf fire sprinklers had been installed\, the outcome could have been so much different………. \nFurther links \n\nBAFSA Sprinkler Saves Review 2021/22\nBusiness Sprinkler Alliance\, Ross-On-Wye Laundry Destroyed in Massive Fire\nSouth Wales Fire and Rescue Service press release sprinkler awareness week
URL:https://www.sprinklersaves.co.uk/saves/newport-industrial-sprinkler-activation/
LOCATION:Newport
CATEGORIES:Industrial
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=Europe/London:20220420T212400
DTEND;TZID=Europe/London:20220420T223300
DTSTAMP:20260429T120354
CREATED:20220424T180349Z
LAST-MODIFIED:20220503T181255Z
UID:10000354-1650489840-1650493980@www.sprinklersaves.co.uk
SUMMARY:Newport Refuse/Bin Store Sprinkler Activation
DESCRIPTION:Fire Rescue Service; South Wales Fire & Rescue Service (SWFRS)\nDate of Incident; April 20\, 2022\nPurpose group; Residential (dwellings) flat\nProperty Category; 10 or more storeys\nHousing provider; Newport City Homes\nType of incident; Fire\nLocation of Incident; Refuse/bin storage store\nTime of incident; 21:24\nSWFRS\, Stop message; 22:33\n\nSWFRS  have reported the above-mentioned fire which started in the premises refuse/bin store with smoke generated from the fire allowed to percolate upwards to  various floors via the bin chute. \nDue to the refuse bin not located in its normal position directly above the sprinkler head\, the system did not immediately activate allowing the fire to be extinguished\, however following the rupture of an aersole can in the refuse bin it trigged the actuation of the sprinkler head extinguishing the fire. \nThe sprinkler head that had actuated had been added to the sprinkler system to provide more effective coverage\, which proved to be the case on this occasion \nThis incident  clearly identifies  the benefits of installing fire sprinklers in refuse/bin stores. \n\nNo injuries reported to residents or firefighter personnel\nFire extinguished\nFire confined to compartment of origin\nBusiness continuity\, minimal disruption to the residents\n\nThis is the sixth reported sprinkler save reported involving a fire within a refuse store/bin room since 19 June 2021 with the fire being contained or extinguished \n\n\n\nFire Rescue Service\nDate of Incident\nPremises Type\nImpact of sprinkler system\nNumber of heads actuated\n\n\nGreater Manchester\n19/06/2021\nResidential block of flats\nContained/controlled\n2\n\n\nGreater Manchester\n07/07/2021\nResidential block of flats\nContained/controlled\n1\n\n\nSouth Wales\n07/08/2021\nResidential block of flats\nExtinguished\nunknown\n\n\nWest Midlands\n08/08/2021\nResidential block of flats\nContained/controlled\nunknown\n\n\nSouth Wales\n27/01/2022\nResidential block of flats\nExtinguished\n1\n\n\nSouth Wales\n20/04/2022\nResidential block of flats\nExtinguished\nUnknown\n\n\n\n  \nDid you know that fire data on fire incidents in Great Britain where sprinklers were reported for the period of 2018/19 to 2020/21\, identified; \n\nRefuse stores account for the highest number of incidents where sprinklers are recorded as being present in fire incidents in purpose-built blocks of flats with 145 incidents\n\nDangers of bin store fires: – It should be noted that the outcome of a communal bin store fire can have a dramatic effect on the safety of the residents\, specifically where refuse chutes and access hatches can sometimes be found directly opening onto protected corridors\, lobbies and stairs\, so providing the potential for the spread of fire and smoke to the common escape routes. \nIt is therefore best practice In these situations: – \n\nAutomatic fire-resisting shutter should be fitted at the base of the refuse chute to restrict the spread of fire and smoke from a fire in the bin room. The shutter should\, as a minimum\, be operated on a fixed temperature fusible link.\nBespoke sprinkler system\, Further protection can be provided by the installation of a sprinkler system located over the bins\, with either frangible bulb or fusible link sprinkler heads\, or open sprinkler heads with water discharge controlled by smoke detectors. The provision of sprinklers should always be considered where access hatches open into protected stairways or lobbies containing more than two flat entrance doors\n\nLinks \n\nBritish Automatic Fire Sprinkler Association: – *Report No 1\, Incident Data Report\, Focus on Sprinklers\nSouth Wales Argus\nSWFRS\n\n*From March 2022\, a series of reports are to be published by BAFSA providing a detailed analysis of ²compound data on fire incidents in Great Britain where fire sprinkler systems were reported as present\, operated over the period of 2018/19 to 2020/21. \nThe aim of the analysis is to focus on identifying trends\, discussion points and insights relating to the use of sprinklers within Great Britain. The outcome of which will evidence that can be used to influence change making the installation of fire sprinklers the norm not the exception \n(To be published:- April 2022\, report No 2  focusing on the location of the fire where sprinklers were reported as being present\, activating inside/outside flats in purpose built block of flats) \n\n\n\n\n² Source: FOI Requests for Incident Recording System Data relating to primary fires attended by FRSs in which sprinklers were present for England\, Scotland\, and Wales for the financial years 2018/19 to 2020/21 \n \n\n\n  \n\n\n  \n  \n  \n  \n  \n  \n  \n  \n 
URL:https://www.sprinklersaves.co.uk/saves/newport-refuse-bin-store-sprinkler-activation/
LOCATION:Newport
CATEGORIES:Residential
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=Europe/London:20220127T234400
DTEND;TZID=Europe/London:20220128T001700
DTSTAMP:20260429T120354
CREATED:20220128T221324Z
LAST-MODIFIED:20220128T222240Z
UID:10000261-1643327040-1643329020@www.sprinklersaves.co.uk
SUMMARY:Newport High Rise Bin Store Sprinkler Save
DESCRIPTION:Fire Rescue Service; South Wales Fire & Rescue Service\nDate of Incident; 27 January 2022\nTime of incident 22:43\nLocation Newport\nGreen Wood Tower block\nOccupancy; Residential High-Rise block\nLocation of fire; Refuse container located beneath the premises rubbish chute\n\nRSP Fire Sprinkler Systems have reported the above-mentioned incident involving the activation of one sprinkler head which successfully extinguished the fire involving a bin store. \nReinstatement of the system following activation\, maintenance is paramount for the safety of the residents a key area that should be considered as part of the consultation process between the sprinkler contractor and client. \nFor this incident it is noted that arrangements were in place allowing the system to be reinstated within an hour of the activation providing a further layer of safety from fire for the residents. \nSouthwales Argus reported that a spokesperson for South Wales Fire and Rescue service said: “At approximately 10.43pm on Thursday\, January 27\, we received reports of a fire in St Julians\, Newport. \n“Multiple crews attended the scene and used specialist equipment to extinguish the fire. \n“The incident concluded at approximately 12.43am.” \nSonia Furzland\, Executive Director of Operations at Newport City Homes said: “Our sprinkler system did its job and put the fire out before it could spread. \n“Our colleagues who were on site last night\, will continue to support South Wales Fire and Rescue Service to investigate the cause of the fire and reduce the risk of this happening again. \n“Working on the advice of our partners at South Wales Fire and Rescue Service\, we installed sprinklers in flats and communal areas in our high rise buildings across the city\, including Greenwood. \nThis is the second reported sprinkler save for Newport involving a bin store\, in a high-rise residential block in the space of 6 months. The previous incident took place on the 7 August 2021. \nDid you know that fire data on fire incidents in Great Britain where sprinklers were reported for the period of 2018/19 to 2020/21\, identify- \n\nRefuse stores account for the highest number of incidents where sprinklers are recorded as being present in fire incidents in purpose-built blocks of flats with 145 incidents\n\nDangers of bin store fires: – It should be noted that the outcome of a communal bin store fire can have a dramatic effect on the safety of the residents\, specifically where refuse chutes and access hatches can sometimes be found directly opening onto protected corridors\, lobbies and stairs\, so providing the potential for the spread of fire and smoke to the common escape routes. \nIt is therefore best practice In these situations :- \n\nAutomatic fire-resisting shutter should be fitted at the base of the refuse chute to restrict the spread of fire and smoke from a fire in the bin room. The shutter should\, as a minimum\, be operated on a fixed temperature fusible link.\nBespoke sprinkler system\, Further protection can be provided by the installation of a sprinkler system located over the bins\, with either frangible bulb or fusible link sprinkler heads\, or open sprinkler heads with water discharge controlled by smoke detectors. The provision of sprinklers should always be considered where access hatches open into protected stairways or lobbies containing more than two flat entrance doors\n\nFurther links \n\nBritish Automatic Fire Sprinkler Association; Year book 2021/22\, Making AFSS the norm\, not the exception \nSouth Wales Fire and Rescue Service\nSouthwales Argus
URL:https://www.sprinklersaves.co.uk/saves/newport-high-rise-bin-store-sprinkler-save/
LOCATION:Newport
CATEGORIES:Residential
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=Europe/London:20210807T083000
DTEND;TZID=Europe/London:20210807T090000
DTSTAMP:20260429T120354
CREATED:20210827T184151Z
LAST-MODIFIED:20210827T184644Z
UID:10000330-1628325000-1628326800@www.sprinklersaves.co.uk
SUMMARY:Newport High Rise Residential Bin Store Fire
DESCRIPTION:South Wales Fire & Rescue Service (SWFRS) were mobilised to a fire following the activation of the sprinkler system involving a refuse bin located on the ground floor of  a 11 storey residential accommodation block  \n\nLela Pirouet\, fire safety officer for Newport City Homes\, informed the South Wales Argus  “Our sprinkler system did its job of being activated and extinguishing the fire before it could spread. There is a sprinkler unit in the bin area\, and it was set off by the heat and smoke going up the chute. \n“Sprinklers save lives\, and we are proud to have started a programme to fit these devices in 2\,500 flats and communal areas over the next three years. ” \n“We believe it was caused by a discarded lit cigarette and that this incident could have been avoided if someone had been more careful.” \n“There are 82 flats in Hillview. When the alarm went off residents from all\, except for the two flats who were close to the smoke\, stayed in their homes and followed the fire safety arrangements for this building. ” \n“I would like to thank the residents for their support during this incident.” \nThis was the second sprinkler save at Hillview involving the residential bin store in two years\, the previous fire took place in August 2019 which is believed to of been caused by another discarded lit cigarette \nBusiness continuity\, on both occasions the  alarm directly linked to the sprinkler save allowed the appropriate immeditae emergency response. The outcome of which allowed SWFRS to be immediately mobilised to the incident.\nNewport City Homes have to be applauded for their current sprinkler project ensuring that their most vulnerable residents are protected from fire following a  further commitment to install automatic sprinkler systems in over 2000 of their properties. \nDangers of bin store fires:- It should be noted that the outcome of a communal bin store fire can have a dramatic effect on the safety of the residents\, specifically where refuse chutes and access hatches can sometimes be found directly opening onto protected corridors\, lobbies and stairs\, so providing the potential for the spread of fire and smoke to the common escape routes. \nIt is therefore best practice In these situations  :- \n\nAutomatic fire-resisting shutter should be fitted at the base of the refuse chute to restrict the spread of fire and smoke from a fire in the bin room. The shutter should\, as a minimum\, be operated on a fixed temperature fusible link.\nBespoke sprinkler system\, Further protection can be provided by the installation of a sprinkler system located over the bins\, with either frangible bulb or fusible link sprinkler heads\, or open sprinkler heads with water discharge controlled by smoke detectors. The provision of sprinklers should always be considered where access hatches open into protected stairways or lobbies containing more than two flat entrance doors\n\nHousing providers across the country are recognising the danger of these type of fires\, London Borough Barking & Dagenham for example \, reduced  the risk by the retrofitting of  sprinklers into all their high rise residential block bin stores\, 22 in total. Following match funding received from the London Fire Brigade (£84\,250) to help fund this initiative. \nFurther information regarding general sprinkler systems can be found in BAFSA publication BIF 06A General Sprinklers Questions \nFurther Links \nSWFRS \nNewport City Homes \nSouth Wales Argus 
URL:https://www.sprinklersaves.co.uk/saves/newport-high-rise-residential-bin-store-fire/
LOCATION:Newport
END:VEVENT