BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Sprinkler Saves - ECPv6.11.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:Sprinkler Saves
X-ORIGINAL-URL:https://www.sprinklersaves.co.uk
X-WR-CALDESC:Events for Sprinkler Saves
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/London
BEGIN:DAYLIGHT
TZOFFSETFROM:+0000
TZOFFSETTO:+0100
TZNAME:BST
DTSTART:20260329T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0100
TZOFFSETTO:+0000
TZNAME:GMT
DTSTART:20261025T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;VALUE=DATE:20260327
DTEND;VALUE=DATE:20260328
DTSTAMP:20260729T022911
CREATED:20260728T163037Z
LAST-MODIFIED:20260728T163037Z
UID:10000565-1774569600-1774655999@www.sprinklersaves.co.uk
SUMMARY:Sprinklers extinguish Leicestershire Specialised Housing fire.
DESCRIPTION:Background \nThe benefit of installing Automatic Water Suppression Systems (AWSS) protecting the most vulnerable residents of our communities was clearly demonstrated following a reported dwelling fire involving a lithium -ion battery by Leicestershire Fire and Rescue Service (LFRS) involving extra care living accommodation\, a form of specialised housing. \nThe fire was contained\, controlled and extinguished by the operation of the building’s AWSS with no injuries reported. Demonstrating the effectiveness of AWSS in controlling fires at an early stage\, significantly reducing the risk to life\, limiting fire spread\, and minimising property damage and preventing the fire from spreading further and allowing a swift\, safe resolution. \nSpecialised housing\, extra care housing schemes has seen demographic shifts\, with people living longer lives. This rise in life expectancy means more residents face mobility issues\, reduced sensory abilities\, and cognitive challenges\, which all heighten both the chances of fire and the risk to individuals during such emergencies. \nThe British Automatic Fire Sprinkler Association\, welcomed the government’s announcement that\, starting in March 2025\, all newly built care homes must have sprinklers installed. However\, we are still concerned that this requirement does not extend to specialised housing\, where residents often face similar risks as those in care homes. Fire safety guidance is provided by the National Fire Chiefs Council for specialised housing\, advocating the use of AWSS\, but it’s not statutory. In England\, the regulations covering AWSS trail behind the rest of the UK\, In Scotland and Wales sprinklers are mandatory for new build specialised housing. \nThis concern was reiterated in the ¹Coroners report aimed at preventing future deaths\, which was sent to the then Rt Hon Michael Gove\, Secretary of State for Levelling Up\, Housing and Communities in March 2023. The report followed the investigation conducted by the coroner into the death of Mr Brian George Harefield aged 85\, who was overcome by smoke\, found unconscious in his flat\, and sadly lost his life. \nThe study\, analysis of ²national fire data\, an in-depth review of fire-related fatalities and severe casualties in England\, 2010/11 to 2018/19 referenced that while there is a lack of recent research on fatal fires\, the available studies consistently identified age\, the presence of an impairment such as physical disability\, smoking\, and alcohol use as key factors on the outcome of the fire\, as they will be less able to respond to a fire. \nThe report raised concerns regarding the lack of mandatory sprinkler systems and other fire-safety measures in extra care and retirement housing particularly for older people with reduced mobility. It acknowledges the government consultation undertaken about sprinklers in care homes\, but the scope of this consultation does not cover to specific risks to those in extra care facilities. \nIn the response from the Secretary of State for Levelling up\, Housing and Communities\, it was acknowledged more evidence is needed on the benefits of sprinklers and other fire protection measures in specialised housing such as extra care facilities. \nA research programme was launched to access whether sprinklers are more effective than alternatives such as improved fire detection alarms or compartmentation\, stage 1 of this research supported requiring sprinklers in all new care homes stage 2 will focus on specialised housing\, including extra care. \nThe findings for stage 2 of this 3research was published in December 2025. The study was considered inclusive\, reflecting a wide range of building types and the project’s complexity and scope. The report also made several recommendations for further research\, including a review of sprinkler system provisions in all types and heights of buildings\, especially within the specialised housing and care home sector. \nThe incident \n\nOn Friday 27th March 2026\, LFRS mobilised three pumping appliances to reports of a fire at a three-storey residential retirement complex\, comprising of 63 self-contained flats\, communal areas.\nOn arrival\, it was confirmed that a fire within a second-floor flat utility cupboard involving a cordless hoover Lithium-Ion battery had been extinguished by the building’s automatic sprinkler system.\nAll residents were accounted for with no injuries reported\n\nSprinkler system  \n\nBS9251:2014\, Residential sprinkler system category 3\, design BS9251:2014\nCoverage\, flats\, communal areas\, ground floor ancillary spaces.\nThe system was installed for compensation deviations from the recommendations within BS9991:2015\n\nConclusion \nThis incident demonstrates that sprinklers can control fires before the fire can escalate in this case involving a lithium-ion battery limiting fire damage\, reducing the risk to people\, firefighters\, property and the environment.                                                  \nReinforcing why the BAFSA\, The National Fire Sprinkler Network and the National Fire Chiefs Council has long advocated for the use of sprinklers in specialised housing and why\, Government should follow the lead of Scotland and Wales expanding sprinkler requirements to include specialised housing. \nProviding further supporting evidence to under pin BAFSA’s advocacy\, turning operational evidence into persuasive tools for policy and parliamentary engagement\, and reinforcing the case for wider sprinkler inclusion within national building policy. \nIn comparison the fire that burnt down the Beechmere extra-care retirement village in Crewe in August 2019 housing 132 apartments for some of our most vulnerable members of our communities\, is a reminder on the danger of fires for this sector. No lives were lost but over 150 residents lost their homes. Sprinklers were not fitted as it was not a statutory requirement under the building regulations. \nSources/further reading \n\nSprinkler saves review 2025/2026\nNFSN Newsletter\nFire Industry Association\, Care home fire sparks call for sprinkler systems\n¹Coroners report to prevent future deaths\n2An in-depth review of fire related fatalities and severe casualties in England\, 2010/11 to 2018/19\n3Research and analysis Fire Safety: Specialised housing and care homes\nNews on the block\, six years after Beechmere-The fire safety gap remains\, BSA Tom Roche BSA\n\nIf you want to make a difference working in the fire sector\, we need your assistance. \nTo make sprinklers the norm and not the exception – we need the evidence. Encouraging FRS and those in the sprinkler community to promote\, collate\, report sprinkler activations to Sprinkler Saves UK which will help to create a central and comprehensive record of fire incidents where sprinklers played their role in containing/controlling or extinguishing the fire. \nIf you hear of a save report it using this link. \n     
URL:https://www.sprinklersaves.co.uk/saves/sprinklers-extinguish-leicestershire-specialised-housing-fire/
LOCATION:leicestershire
CATEGORIES:Home
ATTACH;FMTTYPE=image/jpeg:https://www.sprinklersaves.co.uk/wp-content/uploads/2021/10/Picture-3.jpg
END:VEVENT
END:VCALENDAR