BEGIN:VEVENT
DTSTART;VALUE=DATE:20210928
DTEND;VALUE=DATE:20210929
DTSTAMP:20260429T125507
CREATED:20220124T130843Z
LAST-MODIFIED:20220124T130843Z
UID:10000259-1632787200-1632873599@www.sprinklersaves.co.uk
SUMMARY:High Wycombe Personal Protection System Activation
DESCRIPTION:Date of Incident; 28 September 2021\nFire Rescue Service; Buckinghamshire Fire and Rescue Service\nLocation; High Wycombe District\nLocation of fire; Room\nType of property; flat\nIgnition source; Smoking materials\nAutomatic Fire Suppression System; Personal Protection System (PPS)\n\n  \nThe above-mentioned incident has been reported by Surefire. In July 2019\, Redkite community housing installed a Ultrguard PPS Unit following previous fire incidents involving a resident reducing the level of fire risk faced by the resident.In the early hours of the 28 September 2021\, the resident woke up to smoke a cigarette\, accidentally the lit cigarette dropped onto the floor which caught their slippers to catch light. \nSufficient smoke was generated to activate the two double knock multi sensor alarms detectors and trigger the PPS unit to discharge\, alerting the resident to the fire who was able the vacate the property before the arrival of the Fire & Rescue Service. Thankfully\, no injuries were reported \nTo satisfy the Fire and Rescue Service\, the UltraGuard PPS was chosen to protect this resident as it is certified to LPS 1655 (LPCB Third Party Approval Standard). The importance of a third-party approval standard should not be underestimated as it provides confidence about the design\, performance\, and reliability of these systems in practice. \nRisk Profile/ Personal Emergency Evacuation Plan \nThis incident clearly shows the importance of Identifying those residents that are most vulnerable by the completion of a Personal Emergency Evacuation Plan (PEEP).   This is likely to be completed in premises where the risk to persons in a fire situation is increased due to cognitive or mobility impairments.UltraGuard personal protection systems combine early warning of a fire through smoke detection and water mist for the delivery of suppression. \nEarly detection of a fire is important is important\, as occupants can quickly become overwhelmed by smoke and toxic gases\, the biggest killer in a fire. \nCare needs to be taken to ensure that the risk profile of the vulnerable person is appropriate for PPS. For example\, a vulnerable person who is mobile and living in a multi roomed flat has the potential to be affected by a fire anywhere in their home. As a result\, they would possibly require a full Automatic Water Fire Suppression system (such as a sprinkler system that is designed\, installed and maintained to BS9251 Fire sprinkler systems for domestic and residential occupancies providing full coverage within the flat. \nWhat are Personal Protection Systems? \n\nUnlike sprinkler systems\, PPS are local application watermist fire suppression system combining smoke detection\nDesigned to specifically protect vulnerable individuals with mobility and disability impairments from the threat of fire risk in residential and domestic occupancies who are unlikely to easily escape without assistance in the event of a fire\nDeveloped in response to analysis of fatal fires in dwellings where many victims had physical and/or mental health impairment\nThe publication\, “Guidance on the use\, deployment and limitations of Personal Protection Systems in the homes of vulnerable people” developed by BRE Global and the London Fire Brigade\, to assist in understanding and reducing fire risk to vulnerable people\nBRE Global introduced a loss prevention standard\, LPS 1655 covering the requirements and test methods for the LPCB approval of Personal Protection Systems.\n\nKey components \n\nPortable self contained unit\n3 day battery back-up in case of mains failure\nDelivers 10 minutes of water mist\nActivation\, double knock multi sensor detectors\nNozzle discharges a spray pattern\nCapable of suppressing an area of16m2\, and controlling an area of 32m²\nParameters of the system allow fast burning\, slow smouldering fires to be detected\nFacility for remote monitoring\n\nThis incident clearly identifies the benefits of installing a PPS certified to LPS1655. (LPCB third party approval standard\, a business case has recently been accepted by BSI for a British Standard for PPS. \nLinks \n\nBritish Automatic Fire Sprinkler Association\, Care Homes Animation\nBRE/LFB publication\, “Guidance on the use\, deployment and limitations of Personal Protection Systems in the homes of vulnerable people”\nLoss Prevention Standard\, 1655 Requirements and test methods for the LPCB approval of Personal Protection Watermist Systems.\nPersonal Protection system\, video\n\n 
URL:https://www.sprinklersaves.co.uk/saves/high-wycombe-personal-protection-system-activation/
LOCATION:High Wycombe
CATEGORIES:Residential
END:VEVENT