BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Sprinkler Saves - ECPv6.11.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://www.sprinklersaves.co.uk
X-WR-CALDESC:Events for Sprinkler Saves
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/London
BEGIN:DAYLIGHT
TZOFFSETFROM:+0000
TZOFFSETTO:+0100
TZNAME:BST
DTSTART:20220327T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0100
TZOFFSETTO:+0000
TZNAME:GMT
DTSTART:20221030T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Europe/London:20220421T003600
DTEND;TZID=Europe/London:20220421T133900
DTSTAMP:20260525T052152
CREATED:20220515T202517Z
LAST-MODIFIED:20220516T184510Z
UID:10000360-1650501360-1650548340@www.sprinklersaves.co.uk
SUMMARY:Specialised Housing Sprinkler Activation London
DESCRIPTION:Fire Rescue Service; London Fire Brigade (LFB)\nLFB Resources; Three pumping appliances\nDate of incident; 21 April 2022\nLocation; Hackney\, Pedro Street\nPurpose group; Residential\nUse of property; Specialised Housing\nTime of call; 12:36\nTime of stop; 13:39\nIncident; Fire\nLocation of Incident; Kitchen\nAutomatic Fire Suppression System (AFSS); Residential sprinkler system\n\nLFB have reported the above-mentioned incident that clearly identifies the benefits of installing a residential sprinkler system as part of a holistic approach protecting the most vulnerable residents of our community \nThe Incident \n\nOn arrival operational crews identified a fire within part of a kitchen in a four roomed flat on the second floor of a three-storey specialized housing scheme.\nThe scheme manager was alerted to a fire within the kitchen located within a flat on the second floor.\nThe residential sprinkler system actuated resulting in two heads operating controlling/containing the fire prior to the arrival of operational crews\n\nOutcome \n\nFire\, controlled/containing prior to the arrival of operational crews by the premises suppression system\n30% of the flat damaged by fire\n\nCause of the fire  \n\nAccidental involving an electrical appliance kettle\n\nKey message \n\nResidents in these types of premises are often some of our most vulnerable people in our community:\n\n\nWith physical or cognitive impairment present increased fire risk\nTheir ability to react to fire and/or an alarm\nAbility to escape a fire\n\n\nThis incident clearly identifies the benefits of installing suppression for these type of premises\nIn Scotland and Wales all new build specialised housing homes are required to have sprinklers fitted.\n\n\nThis incident clearly identifies the benefits of installing sprinklers protecting our most vulnerable residents from fire. \nFurther information can be found on sprinklers in the National Fire Chiefs Council\, Specialised Housing Guide\n\n  \n\nBritish Automatic Fire Sprinkle Association\, video extinguishing a chip pan fire\nLFB\, press release\nNFCC\, Specialised Housing Guide\n\nSource\, article \n\nLFB Press release\, information supplied by LFB
URL:https://www.sprinklersaves.co.uk/saves/specialised-housing-sprinkler-activation-london/
LOCATION:Hackney
CATEGORIES:Residential
END:VEVENT
END:VCALENDAR