BEGIN:VEVENT
DTSTART;VALUE=DATE:20241201
DTEND;VALUE=DATE:20250101
DTSTAMP:20260501T052555
CREATED:20250106T140300Z
LAST-MODIFIED:20250106T140300Z
UID:10000496-1733011200-1735689599@www.sprinklersaves.co.uk
SUMMARY:Gloucestershire Lithium Battery HMO Sprinkler Save
DESCRIPTION:Obi Selassie\, GFRS Station Manager “If it was not for the activation of the sprinkler system extinguishing the fire before the arrival of the fire service\, we could be discussing a different outcome for this incident\, The benefits of sprinklers should not be underestimated they save lives and reduce injuries\, protect firefighters.” \n Summary \nGloucestershire Fire and Rescue Service (GFRS) have reported that a fire at a house of multi occupancy (HMO) in December 2024 was successfully extinguished by the activation of the premises residential sprinkler system\, believed to have been caused by the failure of a e-bike lithium battery which was on charge within a ground floor studio flat with no injuries reported. \nLithium battery fires can spread quickly out of control developing into large fires within a short period of time. If it was not for the foresight of the landlord to retrofit a residential sprinkler system as part of a package of fire safety measures the outcome of this incident could have been so different. HMO accommodation is undoubtedly a challenging environment from a fire safety perspective with their own individual challenges when a property is let to multiple individual tenants due to the higher fire risk. \nA similar incident reported by London Fire Brigade (LFB) resulted in a e-bike battery explosion which destroyed a family home days before Christmas identifying the catastrophic consequences that can occur if e-bikes and e-scooters are not charged or stored safely\, sprinklers were not installed. \nFootage from a doorbell camera captures how quickly the property became engulfed in fire\, three people were inside the house when the e-bike battery burst into flames on the first floor. One person escaped unharmed through the front door\, but two others in a converted loft were forced to climb through a skylight on to the roof. One male fell from the roof and suffered serious injuries\, while a woman slipped but was caught by a firefighter and later treated for smoke inhalation. \n \nThe growing risk of e-bike and e-scooter involving lithium battery fires should not be underestimated which can develop into significant and unstoppable runaway fires. \nIt should be remembered the installation of a life safety sprinkler system is to reduce the rate of heat and smoke\, allowing more time for the occupants to escape to safety or be rescued. \nFire protection is dependent on both passive and active fire systems such as sprinklers working in unison providing a further layer of safety from fire as part of a package of fire safety measures\, in reducing the impact of fire on people\, firefighters\, property and the environment. \nFurther guidance on suppression and extinguishing can be found in the Fire Industry Association Guidance Note on Lithium-Ion battery fires\, which references that sprinkler protection of lithium-ion batteries is outside the scope of current sprinkler design standards\, specialist standards are being developed such as NPFA 855. \nThis incident provides further evidence that the main functional objectives of a life safety sprinkler system were achieved. \n\nReducing the rate of heat and smoke\, containing and controlling the fire\nReducing the likelihood of a fire spreading beyond the room of origin\nFirefighters operated without due risk to either effect rescue or assist evacuation\nPrevent conflagration\n\nAdding further weight to the reliability and effectiveness of sprinkler systems following the two recent reports conducted ¹Optimal Economics\, and commissioned by the National Fire Chiefs Council\, National Fire Sprinkler Network into the performance\, reliability\, and effectiveness of sprinkler systems in controlling and extinguishing fires. \nThe reports found that: \n\nSprinklers are 99% efficient in extinguishing or controlling a fire.\nSprinklers are 94% efficient in their ability to operate.\n\nThe Incident  \n\nDate of incident; December 2024.\nIncident; Fire.\nAddress; Gloucestershire\nOccupancy: House of multi occupancy\nLocation of fire; Bedsit.\nImpact of AFSS; Contained/controlled.\nNumber of sprinkler heads operated; 1.\n\nSummary of Incident  \n\nFire crews were mobilised to reports of a confirmed fire following an emergency call 999 call.\nOn arrival the incident commander established that the seat of the fire was within a ground floor studio bedsit.\nUpon entry\, firefighters wearing breathing apparatus established that\n\n\n1 sprinkler head had activated within the room of origin\, containing/controlling and extinguishing the fire.\n10% fire/heat and smoke damage sustained to the area in vicinity of the seat of the fire.\n\n\nThe resident self-evacuated the premises prior to the arrival of the emergency services.\n\n\nThe fire was contained to the room of origin\, allowing tenable conditions for the remaining occupants within the property to make their way to a final place of safety via the common ways.\nThe cause of the fire involved a e-bike lithium battery which was on charge.\nFirefighting media\, 1 hose reel jet was used to extinguish remaining hot spots.\n\n\nOnsite information was not available allowing firefighters to assist in the management of water from the activation of the sprinkler system allowing the isolation of the sprinkler isolation valve.\nMajor protracted incident everted allowing FRS resources to be released\, redeployed to attend emergency incidents.\nThe building was reoccupied at the conclusion of the incident\nAlternative accommodation was required for the tenant whilst minor redecoration works were completed to their accommodation.\n\n The following advice is intended for building managers\, individuals who have responsibility for fire safety within a building. \nPremises Emergency Plan \nThe problem\, post fire sprinkler activations reported where buildings have been identified as affected by water egress following the successful activation of the sprinkler system containing\, controlling or in some cases extinguishing the fire\, predominately due to. \n\nPoor business continuity management\, inadequate onsite emergency planning by the building manager or responsible person for the fire safety arrangements within a building.\nAllowing onsite information to be available for firefighters to interact with the building active fire safety measures namely automatic water fire suppression systems.\n\nThere is now a high probability that firefighters will attend a variety of incidents where sprinklers systems are reported as present and having an impact within these types of buildings. \nThe provision of a robust emergency plan will allow an immediate emergency response to be actioned by the fire rescue service to assist in the management of water from the activation of the sprinkler system following a fire or even following the unlikely likelihood of un-intentional release of water\, due to the knock-on effect this can have on a business or occupancy \nDebunking the myth that water damage following the actuation of the sprinkler system will be more expensive than the actual damage resulting from the fire. \nReinstatement of the Fire Protection Measures \n\nIt is paramount that fire protection measures in buildings can function effectively in the event of a fire. To achieve this the premises emergency plan should include that arrangements are in place allowing the immediate reinstatement of the sprinkler system.\nIt is a requirement of the Regulatory Reform (Fire Safety) Order for the responsible person to implement the appropriate arrangements for the effective planning\, organisation\, control\, monitoring of the preventive and protective measures.\nAny delay could compromise the safety of the occupants in the event of a further fire within the building due to the sprinkler system being offline.\n\nFurther detailed guidance on Sprinkler protected buildings can be found in the BAFSA Information file\, A guide for Responsible Persons and Duty Holder. \nSources/further reading.  \n\nSprinkler Saves Review 2023/2024\nSprinkler Saves Summer Update No 6\n¹Efficiency and Effectiveness of Sprinkler Systems in the United Kingdom: An Analysis from Fire Service data \nBAFSA Information file\, A guide for Responsible Persons and Duty Holder.\nGFRS\, Sprinklers\nYou tube London family home destroyed by e-bike battery days before Christmas\nLFB Charge safe e-bike and e scooter safety advice\nE bike house fire\, LFB/X\nGuidance note FIA Guidance on Lithium-Ion Battery Fires.\n\nIf you want to make a difference working in the fire sector\, we need your assistance…… \nTo make sprinklers the norm and not the exception – we need the evidence. Encouraging FRS and those in the sprinkler community to promote\, collate\, report sprinkler activations to Sprinkler Saves UK which will help to create a central and comprehensive record of fire incidents where sprinklers played their role in containing/controlling or extinguishing the fire. \nIf you hear of a save report it using this link. \nCredit to GFRS for reporting this incident allowing the benefits of sprinklers to be reported to a wider audience raising awareness of the good work that sprinklers do and help in our continued campaign to lobby government to introduce tougher sprinkler rules making the installation and retrofitting of sprinklers mandatory in all buildings we are particularly concerned about: \n\nBuildings housing vulnerable residents\nResidential buildings\nSchools\nCarparks\nStorage and warehouses\nHospitals\n\n      \n 
URL:https://www.sprinklersaves.co.uk/saves/gloucestershire-lithium-battery-hmo-sprinkler-save/
LOCATION:Gloucestershire
CATEGORIES:Residential
END:VEVENT