BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Sprinkler Saves - ECPv6.11.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:Sprinkler Saves
X-ORIGINAL-URL:https://www.sprinklersaves.co.uk
X-WR-CALDESC:Events for Sprinkler Saves
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/London
BEGIN:DAYLIGHT
TZOFFSETFROM:+0000
TZOFFSETTO:+0100
TZNAME:BST
DTSTART:20210328T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0100
TZOFFSETTO:+0000
TZNAME:GMT
DTSTART:20211031T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;VALUE=DATE:20211104
DTEND;VALUE=DATE:20211105
DTSTAMP:20260429T145401
CREATED:20211223T185503Z
LAST-MODIFIED:20211223T190107Z
UID:10000343-1635984000-1636070399@www.sprinklersaves.co.uk
SUMMARY:Elephant & Castle Sprinkler Activation
DESCRIPTION:Date of incident: 4 November 2021\nTime of Call: 10:56\nCause of fire: Unsafe disposal of smoking materials\nOccupancy: 32 Storey residential block of flats\nLocation of fire: 18 floor\, balcony\nSprinkler system: Wet pipe\, water supply: – suction tank and pump\n1 x residential head activated\n\nLondon Fire Brigade have reported the above-mentioned incident involving the attendance of eight fire engines and 6o firefighters extinguishing the fire using 3 jets via wet rising main\,  preventing external fire spread from the balcony to the residential dwelling. \nFollowing commencement of firefighting operations\, products of combustion entered the four -roomed flat activating the sprinkler head\, identifying the clear benefits of sprinklers for firefighters preventing flashover\, fire spread and providing a further layer of safety from fire during firefighting operations. \nThe benefits of sprinklers involving a previous balcony fire was clearly demonstrated in the LFB report to raise awareness in the residential sector of the beneficial/effectiveness impact that incorporating Automatic Fire Suppression Systems can have in a multi-point residential high-rise fire. Where in the space of 19 minutes from time of call\, 5 apartments were exposed to fire and heat activating 12 sprinkler heads \nThis incident identifies the importance of identifying\, replacing combustible materials that are combustible such as timber\, composite balcony decking. Guidance is now available from the government for owners of residential buildings advising that “the removal and replacement of any combustible material used in balcony construction is the clearest way to prevent external fire spread from balconies” \nThe dangers of balcony fires\, external fire spread were identified in the BRE publication “Fire Safety Issues with balconies that identified several incidents of balcony fires \nLinks; \n\nBAFSA Press release West Hampstead balcony fire\nLondon Fire Brigade\, press release\nMinistry of Housing\, Communities & Local Government\, Building safety advice for building owners\, including fire doors\nBRE 2016 report\, “Fire Safety issues with balconies”
URL:https://www.sprinklersaves.co.uk/saves/elephant-and-castle-balcony-fire-sprinkler-activation/
LOCATION:Elephant & Castle\, SE17
CATEGORIES:Residential