BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Sprinkler Saves - ECPv6.11.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://www.sprinklersaves.co.uk
X-WR-CALDESC:Events for Sprinkler Saves
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/London
BEGIN:DAYLIGHT
TZOFFSETFROM:+0000
TZOFFSETTO:+0100
TZNAME:BST
DTSTART:20230326T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0100
TZOFFSETTO:+0000
TZNAME:GMT
DTSTART:20231029T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Europe/London:20230618T203900
DTEND;TZID=Europe/London:20230618T223900
DTSTAMP:20260531T041520
CREATED:20230626T182037Z
LAST-MODIFIED:20230626T193321Z
UID:10000422-1687120740-1687127940@www.sprinklersaves.co.uk
SUMMARY:Scotland Care Home Sprinkler Activation
DESCRIPTION:Image credit Discovery Fire Sprinklers \n\n\nFire Recue Service; Scottish Fire & Rescue Service (SFRS)\nIncident; Fire\, white goods appliance\nWhen; 18 June 2023\nTOC; 20:39\nWhere; Dunblane Scotland\nType of Premises; Residential Care Home\nAutomatic fire suppression System: BS9251\n\n  \n\nDiscovery Fire Sprinklers/SFRS have reported the above-mentioned incident involving a white goods appliance (tumble dryer) which caught fire in the premises laundry room located on the ground floor\nThe premises consists of 2 floors providing accommodation for up to 14 adults which is of stone-built construction.\nThree fire appliances were mobilised by SFRS\, committing a team of 4 Breathing Apparatus for firefighting and ventilation purposes on arrival.\nFirefighting media consisted of one hose reel jet\n\nIt was identified that the fire was contained to the room of origin by the activation of one concealed sprinkler head which actuated containing/controlling the fire before the arrival of the SFRS. \nThe cause of the fire was due to the appliance overheating due to the build-up of lint\, no injuries were reported. \nSprinkler Installation details \n\nInstalled to BS9251:14\nCategory 3\nSprinkler head\, Rapid drop RD208\nWater Supply tank/pump\n\n       \n\nimage 1:- activation of sprinkler head with cover plate detached from its housing\nImage 2 Sprinkler head replaced with cover plate visible\n\nImages credit Discovery Fire Sprinklers images \nThe benefits of the sprinkler systems clearly identified for this incident: \n\nFire was suppressed\, contained to the room of origin\, preventing flash over.\nThe safety of firefighters reinforced\, providing firefighters time to implement their tactical action plan.\nStaff provided with extra time to implement the premises emergency action plan.\n\nThe images clearly indicate the benefits of passive\, active fire protection measures working in unison for this incident. \n\nSprinklers\n\n\nMinor smoke stains sustained to the room of origin with a slight burn visible on the vinyl floor directly below where the appliance was positioned.\nSprinkler head visible following the successful operation\, detachment of the cover plate.\nSprinkler pattern visible at ceiling level.\n\n\nFire door\n\n\nSlight smoke stains to the inside of the door\, positive self-closing device fitted\, indicating the door was closed at the time of the fire\,\n\n\nAutomatic Fire Detection \n\n\nDetector head located directly above the seat of the fire.\n\nThis is the second reported fire to SPRINKLER SAVES UK involving a residential care home within 17 months involving a tumble dryer which caught fire in the premises laundry room. The fire was contained to the room of origin by the residential sprinkler system which actuated suppressing the fire before the arrival of NFRS. No injuries were reported. Full details of this incident can be found by clicking the Wellingborough residential care home sprinkler save in the links section. \nLegislation \nFollowing the tragic events of The Rosepark Care Home Fire in Uddingstom\, South Lanarkshire in 2004 that sadly killed 14 residents\, Scotland responded by making the installation of sprinklers mandatory in all new care homes. Unfortunately\, in England there is no requirement for the installation of sprinklers to protect the most vulnerable residents from fire. \nHowever\, BAFSA strongly welcomes the recent government consultation published on the 23 December 20222 proposal to recommend residential sprinklers in new care homes as part of this consultation process\, we would encourage government to support the mandatory retrofitting of sprinklers in existing care homes for England. \nNew Grange Care Home Fire\, Sprinklers were not fitted \nThe danger of care home fires was clearly demonstrated following the Newgrange Care Home Fire 2017 highlighted in the NFCC Sprinkler Toolkit as part of sprinkler week \n\n\n\nIn April 2017\, a Cheshunt care home in Hertfordshire was the scene of a major fire. The fire broke out in the early hours of the morning The care home was occupied by 35 residents. Operational response required 12 fire engines and on arrival crews found residents in their rooms\, many still in bed and unable to move due to their physical condition. Firefighters rescued 33 elderly and \nimmobile residents. Two residents died as a result of the fire. \nIf sprinklers had been fitted in this care home there is strong chance that no residents would have lost their lives. As a result of this fire the coroner raised concerns that sprinkler systems are not mandatory in care homes. Hertfordshire Fire and Rescue Service recommended sprinklers be installed. The home was rebuilt – without fire sprinklers installed. \n\n\n\n \nImage credit HFRS \nSource NFCC Sprinkler tool Kit \nLinks— \n\nBritish Automatic Fire Sprinkler Association \, Sprinkler Saves Review 2022/23\nFire Sprinklers Greater London Review 2018-2021\nWellingborough residential care home sprinkler save\nRose Park Care Home Fire Presentation David Mallin Lothian and Boarders Fire & Rescue Service\nGovernment consultation\, recommend sprinklers in care homes\, remove national classifications from Approved Document B\nNFCC Consultation response dated 17 March 2023\n\n  \n 
URL:https://www.sprinklersaves.co.uk/saves/scotland-care-home-sprinkler-activation/
LOCATION:Dunblane
ATTACH;FMTTYPE=image/jpeg:https://www.sprinklersaves.co.uk/wp-content/uploads/2023/06/Carehome-fire-northest-image-3.jpeg
END:VEVENT
END:VCALENDAR