BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Sprinkler Saves - ECPv6.11.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://www.sprinklersaves.co.uk
X-WR-CALDESC:Events for Sprinkler Saves
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/London
BEGIN:DAYLIGHT
TZOFFSETFROM:+0000
TZOFFSETTO:+0100
TZNAME:BST
DTSTART:20220327T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0100
TZOFFSETTO:+0000
TZNAME:GMT
DTSTART:20221030T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Europe/London:20220820T201600
DTEND;TZID=Europe/London:20220820T211600
DTSTAMP:20260416T085007
CREATED:20220825T203024Z
LAST-MODIFIED:20220825T203024Z
UID:10000389-1661026560-1661030160@www.sprinklersaves.co.uk
SUMMARY:Multi Occupancy Entertainment Centre Sprinkler Activation
DESCRIPTION:Fire Rescue Service; West Yorkshire Fire Rescue Service (WYFRS)\nIncident;  fire involving\, electrical appliance\nWhen; 20 August 2022\nTime of call; 20:16\nWhere\, Castleford\, Gravity Trampoline Park\nType of premises; Multi Occupancy Entertainment Centre\nUse of Unit; Trampolining Park\nAutomatic fire suppression System; Fire Sprinklers\n\nWYFRS have reported the above-mentioned incident resulting in the activation of the premises commercial sprinkler system \nIncident \n\n3 x Pump fire with pumping appliances attending from local stations\nFire within a commercial unit\, indoor sporting venue\nCommercial Sprinkler system actuated following a fire involving a electrical appliance which spread to rubber matting\n200 people evacuated the premises following the activation of the premises fire alarm system\n\nSprinkler system \n\nInterfaced with the fire detection and fire alarm system allowing the alarm to be raised\nWater supply\, designated suction tank\nExtinguished the fire\, with no further firefighting action required from WYFRS on arrival\n3x Pendent Sprinkler heads actuated\n\n Benefits of the sprinkler system  \n\nRapidly reduced the rate of production of heat and smoke allowing the fire service crucial time to implement their operational tactical plan\nFire damage was limited to the area in the vicinity of the seat of the fire\nThe fire did not spread from the compartment of origin\nNo injuries reported\, complex evacuation plan successfully implemented\n\nBusiness Continuity \n\nThis incident clearly demonstrates the importance of protecting muti-occupancy entertainment centres with a commercial sprinkler system.\nPreventing a minor small fire from accelerating into a major fire with only minor disruption to the unit directly involved with the fire\, The business is reported to reopen on the 26 August\nOther commercial units/activity sites were not affected\, remain opened as usual following the fire\nSevere damage\, loss of earnings and ongoing disruption to the business was avoided\nIf sprinklers were not fitted the outcome of the fire could have resulted in the  buildings unit being either completely or partially destroyed\n\nLinks \n\nBAFSA\, Fire Data reports\, provide a detailed analysis of compound data1 on fire incidents in Great Britain where sprinklers systems were reported over the period of 2018/19 to 2020/21.\nWest Yorkshire Fire Rescue Service\nBusiness Sprinkler Alliance; FIRE AT SUFFOLK INDUSTRIAL ESTATE IMPACTS BUSINESSES
URL:https://www.sprinklersaves.co.uk/saves/multi-occupancy-entertainment-centre-sprinkler-activation/
LOCATION:Castleford
CATEGORIES:Commercial
END:VEVENT
END:VCALENDAR