BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Sprinkler Saves - ECPv6.11.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:Sprinkler Saves
X-ORIGINAL-URL:https://www.sprinklersaves.co.uk
X-WR-CALDESC:Events for Sprinkler Saves
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/London
BEGIN:DAYLIGHT
TZOFFSETFROM:+0000
TZOFFSETTO:+0100
TZNAME:BST
DTSTART:20220327T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0100
TZOFFSETTO:+0000
TZNAME:GMT
DTSTART:20221030T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Europe/London:20220505T212200
DTEND;TZID=Europe/London:20220505T223000
DTSTAMP:20260615T085835
CREATED:20220510T191523Z
LAST-MODIFIED:20220510T191523Z
UID:10000356-1651785720-1651789800@www.sprinklersaves.co.uk
SUMMARY:Carlisle Factory Sprinkler Save
DESCRIPTION:Fire Rescue Service; Cumbria Fire & Rescue Service (CFRS)\nDate of incident; 5 May 2022\nLocation; Carlisle\nPurpose group; Single story factory\nTime of call 21:22\nIncident; Fire\nLocation of Incident Curing Department conveyor belt production line\nAutomatic Fire Suppression System; Sprinklers\n\nCFRS have reported the above-mentioned incident that clearly identifies the benefits of installing a bespoke commercial sprinkler system as part of a holistic approach to protect business from the impact of a premises fire. \nThe Incident \nFollowing the activation of the premises fire alarm system\, it was identified that an overheated bearing in the conveyor had caught light\, creating a series of knock-on events\, \n\n1x sprinkler head activated\nPremises conveyor belt automatically shut down\nThe activation of a set of fire doors on the conveyor production line preventing fire spread from the compartment of origin\n\nOutcome \n\nFire contained/extinguished prior to the arrival of CFRS\nFire service intervention minimal\nAttendance of only 2 pumping appliances\, crews checking for hot spots only\nImpact on business disruption minimal\nEstimated value of damage less than £10\,000\nEnvironmental impact minimal\n\nSprinkler system \n\n1X pendent head actuated\nWater supply\, private bore hole and reservoir\n\nBusiness continuity \nIs paramount\, following any fire\, you must ask yourself what the financial impact of the lost building is\, its contents\, the business disruption and jobs and the cost to the environment. Specifically in the light of the recent climate meeting in Glasgow. \nOn this occasion\, \n\nImpact on business was minimal with the production line shut for only 8 hours\,\nThe sprinkler system reinstated\, checked and serviced at 04:30 hours.\nyour attention is drawn to the article by Tom Roche Secretary of the business sprinkler alliance\, “when a building burns down what is the cost to the environment” see link below\n\nYou have to ask the question what would the outcome of been if sprinklers had not been installed? \nLinks \n\nBritish Automatic Fire Sprinkle Association\nInformation file\, BIF 26 Sprinklers\, and the insurance industry  \nCFRS\nBusiness Sprinkler Alliance\nTom Roche Secretary of the business sprinkler alliance\, “when a building burns down what is the cost to the environment’
URL:https://www.sprinklersaves.co.uk/saves/carlisle-factory-sprinkler-save/
LOCATION:carlisle\, United Kingdom
CATEGORIES:Industrial